Victron Fans are noisy on low RPM

General Viewed: 34

The fan in the earlier MultiPlus-II, EasySolar-II and Quattro-II units can be noisy, especially at low fan speeds.

The electronics design in the recent MP-II/ES-II/QUA-II units has been improved, fixing this problem.

Installing the Fan PWM converter will reduce noise for all fan speeds except full speed. In other words, at 100%

fan speed, there is no difference between the old and the new situation. Same with the improved electronics in

the MP-II/ES-II/QUA-II units: fan control when running at reduced speeds has a problem which is now fixed.

2. Affected models and serial numbers

All units with a serial number before and including the serial number listed below have the issue electronics;

which can be solved by the retrofit.

All units with a newer serial number, or units not listed below, feature the improved fan control. Mounting the

retrofit kit in such unit, will not further reduce the noise level.

Part number Article description Affected serial nrs (up to and including) (1)

PMP122305010 MultiPlus-II 12/3000/120-32 230V HQ2236

PMP122305100 MultiPlus-II 12/3000/120-50 2x120V All

PMP122305102 MultiPlus-II 12/3000/120-50 2x120V (UL) HQ2226

PMP122305110 MultiPlus-II 12/3000/120-50 120V All

PMP122305120 MultiPlus-II 12/3000/120-50 120V All

PMP242305010 MultiPlus-II 24/3000/70-32 230V HQ2227

PMP242305100 MultiPlus-II 24/3000/70-50 120V HQ2231

PMP242305130 MultiPlus-II 24/3000/70-50 2x120V HQ2231

PMP242306000 MultiPlus-II 24/3000/70-32 230V GX HQ2230

PMP242307010 EasySolar-II 24/3000/70-32 MPPT 250/70 GX HQ2230

PMP242505010 MultiPlus-II 24/5000/120-50 230V HQ2229

QUA242505010 Quattro-II 24/5000/120-50/50 230V HQ2229

PMP482305010 MultiPlus-II 48/3000/35-32 230V HQ2225

PMP482305100 MultiPlus-II 48/3000/35-50 120V All

PMP482306000 MultiPlus-II 48/3000/35-32 230V GX HQ2227

PMP482307010 EasySolar-II 48/3000/35-32 MPPT 250/70 GX HQ2228

PMP482505010 MultiPlus-II 48/5000/70-50 230V HQ2224

PMP482506000 MultiPlus-II 48/5000/70-50 230V GX HQ2230

PMP482507010 EasySolar-II 48/5000/70-50 MPPT 250/100 GX HQ2227

QUA482504010 Quattro-II 48/5000/70-50/50 230V HQ2229

PMP482805000 MultiPlus-II 48/8000/110-100/100 230V HQ2231 (See note 2 below)

PMP483105000 MultiPlus-II 48/10000/140-100/100 230V HQ2228 (See note 2 below)

All other models Better fan control from start of production.

Format of the serial number is HQyywwzzzzz in which yy is the year, ww is the week number, and zzzzz is random.

The serial number (SN) can be found on the label on the enclosure, on the label on the carton and in the

VictronConnect App.

Install the Retrofit kit, SPR00090 – PCBA MGR50_MP_II fan PWM converter 40KHz, to reduce the fan noise at

low RPM.

Distributors can order the fan PWM converter PCBA free of charge. Find it on E-Order as part number SPR00090.

Ramping production of this PCBA will take time, don’t over stock this part.

http://C:\Users\josh\OneDrive – Zonna Energy\Downloads\Victron Energy